1 GENERAL
1.1 Technical data
Power class
002F 003F 004F 005F 007F 011F 015F 018F 022F 030F 037F 045F 055F 075F 090F 110F
Power (kVA) at 400V
4.5 5.5 7 9 13 17 22 29 33 40 50 60 75 100 120 150
Output current In (A)
6.5 8 10 13 18 24 32 42 48 60 75 90 110 150 180 210
Max. current 1min (A)
10 12 15 20 27 36 48 63 72 90 113 135 165 225 270 315
Overloadability 1.5 x In , 1min/10min
Max. output voltage Equal to supply voltage
Supply
Supply voltage 380-500VAC
Allowable voltage fluctuation +/- 10%
Nominal supply frequency 50/60Hz +/- 5%
Signal input levels
Digital controls S1, S2, DIA3, DIA4, DIA5, DID1, DID2, DID3, DID4, DID5: 42 … 240VAC; 15mA
Analog references
AIN1: -10 … +10V and AIN2: 0 … 10V; 200kΩ; accuracy 0.5%
Encoder feedback
EA+/- and EB+/-; 0/24V; 3kΩ; floating differential inputs
Control features
Control method Open loop or closed loop vector control
Frequency control range 0 ... 250Hz
Frequency command Potentiometer, motor potentiometer, 2-4-step controller or 0 ... 10V analog signal
Limit switch functions Slowdown and stop limit inputs for both directions
Speed control range Open loop vector control
s
N
... 100% (s
N
= motor nominal slip)
Closed loop vector control
0 ... 100%
Speed accuracy Open loop vector control
1% of nominal speed at speed range 10 ... 100%
1/3 of motor nominal slip at speed below 10%
Closed loop vector control
0.01% of nominal speed
Extended speed range 100 ... 200%
Braking torque 150%
Protections
Stall prevention During acceleration and constant speed
Motor overload protection Thermistor based temperature measurement
Overload protection Fault is detected if the current momentarily exceeds 280% of rated current
Undervoltage / blown fuse Fault is detected if DC voltage drops below 333V
Overvoltage protection Fault is detected if DC voltage exceeds 911V
Momentary power loss Immediate fault stop
Inverter overtemperature Temperature sensor on the heat sink
Mechanical brake Circuit breaker
Braking transistor Electronic supervision for the braking chopper and for the braking resistor
Ground fault Provided by electronic circuitry
Overspeed / stall,
speed difference supervision Independent measurement using pulse wheel or encoder
Ambient conditions
Ambient temperature
-10°C ... +55°C (14°F ... 131°F) for ED≤60%
Storage temperature
-40°C ... +60°C (-31°F ... 140°F) dry
Humidity <95%RH (no condensation)
Altitude Maximum 1000m at In. Above 1000m: In reduces 1% per each 100m.
Above 3000m: consult factory.
Vibration Operation: maximum displacement amplitude 3mm at 2-9Hz.
Maximum acceleration amplitude 0.5g (5m/s²) at 9-200Hz
Conforms to LV and EMC directives.