Switch S4 - 2 Slowdown mode
Operation Description
0 Direction memory on
When the power is turned off, the limit switch status is saved. When power is turned
back on and limit switch circuit is opened, driving is allowed with maximum speed in
the opposite direction.
1 Direction memory off
When the limit switch circuit is opened, the maximum speed is limited in both
directions until the limit switch circuit is closed.
WARNING
Do not turn the direction memory on when a limit switch can be activated
without running the equipment, for example, by an anti collision device or a
tandem drive application.